Ventilation
New powerful and efficient heat pump at an attractive price. The outdoor unit is extremely compact even for the capacity size of 16,2 kW.
Appearance of the outdoor unit 16.2kW
Compactness and efficiency - this is what modern heating technology looks like today. Mycond BeeHeat is a split system: the heat pump consists of outdoor and indoor units.
The outdoor unit with a capacity of 16.2 kW (A7/W35) has extremely compact dimensions, which significantly simplifies installation.
When upgrading the heating system, a heat pump can be added as an additional heat source. In this case, the existing boiler operates only at particularly low outdoor temperatures, while the heat pump operates for the entire heating season. Such a heating system is more reliable and economical to operate.
Heat pumps use many solutions to ensure maximum user comfort.
The Mobile App allows you to very easily control the heat pump and the entire system from your smartphone:
Remote control allows you to constantly view the operation of the device on your smartphone.
Heating Curve Function
Using Heating Curve Logic, users can set up the system to meet their optimum comfort levels based on the changing heat demand, insulation levels, etc.
Heat pump can adjust the outlet water temperatures based on the ambient temperature, by continually monitoring and adjusting it in opposite directions with the current ambient temperature levels to ensure the optimum in the living spaces.
Room Temperature Control Function
In addition to the water temperature control function, users can also choose to control the heating water temperatures, by setting it on their controller pads based on the room temperature.
In this mode heat pump will manage the outlet water temperature and work towards achieving and maintaining the set room temperature.
Auto Heat/Cool Switch-over Mode
BeeHeat has Automatic Heat/Cool Switch-over function to enable the user a truly unattended automatic operation of the system.
Sleep Mode
In this mode BeeHeat heat pump adjust outlet water temperature or room temperature to save energy and lowers the operation noise by reducing the working speed of the compressor and fan motor for optimum sleeping comfort.
Economical Operation
As the ambient temperature drops, the heating efficiency of heat pumps drops along. In some countries or regions, when ambient temperature drops to a certain level, usage of other heating sources, like a gas boiler, may become more economical than the use of the heat pump.
BeeHeat unit allows the user to stop running the heat pump and turn on other heating sources, when the ambient temperature drops to a certain level.
Frame with tray for outdoor unit
Specifications | Units | MHS-N6BH MHS-U6BH |
MHS-N8BH |
MHS-N10BH MHS-U10BH |
MHS-N12BH |
MHS-N14BH |
MHS-N16BH MHS-U16BH |
Heating capacity (А7/W35) Coefficient of performance COP (А7/W35) |
kW
|
6,0 4,89 |
7.9 4,51 |
9,7 4,62 |
12,1 4,51 |
14,3 4,61 |
16,2 4,41 |
Heating capacity min/max (А7/W35) | kW | 2,8-7,1 | 3,4-8,9 | 3,6-10,2 | 5,6-14,0 | 5,9-15,0 | 6,5-16,5 |
Maximum heating capacity (А-7/W35) | kW | 4,9 | 6,8 | 8,3 | 10,3 | 12,3 | 13,5 |
Coefficient of performance COP (А-7/W35) | 2,94 | 3,05 | 3,1 | 2,7 | 2,7 | 2,6 | |
Maximum cooling capacity (A35/W7) | kW | 6,0 | 7,7 | 9,6 | 10,9 | 12,7 | 14,0 |
Energy efficiency ratio EER (A35/W7) | 2,94 | 2,78 | 2,94 | 2,66 | 2,55 | 2,45 | |
Operating ambient temperature (heating) | °C | -25…+43 | -25…+43 | -25…+43 | -25…+43 | -25…+43 | -25…+43 |
Operating ambient temperature (cooling) | °C | +8…+43 | +8…+43 | +8…+43 | +8…+43 | +8…+43 | +8…+43 |
Maximum flow temperature | °C | +60 | +60 | +60 | +60 | +60 | +60 |
Refrigerant type | R32 | R32 | R32 | R32 | R32 | R32 | |
Power supply | V / Hz | 230/50 | 230/50 | 230/50 | 400/50 | 400/50 | 400/50 |
Sound power level (indoor/outdoor unit) | dB(A) | 42/58 | 42/59 | 42/60 | 42/64 | 42/65 | 42/68 |
Energy Efficiency Class | |||||||
– low temperature application (W35) | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | |
– medium temperature application (W55) | A++ | A++ | A++ | A++ | A++ | A++ |